A GoodWe error appears in the PV Master app, on the display or in an alert email. Utility Loss means the inverter cannot see the grid (normal in a brownout), Over Temperature means it is too hot, and Back-Up Over Load means too much on the backup output. Messages about leakage, insulation, ground, arcs or reversed strings are safety issues: switch off at the external switches and call your installer. This guide covers the ES and ET series, with meanings from GoodWe’s own manuals and the checks that are safe for an owner.

Updated November 23, 2026 · Messages checked against GoodWe manuals November 23, 2026 · By the SunTipid team · Not engineering advice

Safety first: read the message, do the simple checks, and stop there. Never open the inverter, touch its terminals or cables, or work on the panels, battery or wiring yourself. GoodWe’s own checks often use a multimeter on live wiring, which is a job for a qualified person only. Anything beyond switching off, restarting and reading the display or app belongs to your installer or a licensed professional electrical engineer (PEE). This guide gives no wire sizes and no breaker ratings.
Lists coveredES, ET, ES G2From 3 GoodWe manuals
Safe restartAC off, DC off, wait 5 minThen switch both back on
NeverOpen the inverterCall your installer or a PEE
Not checkedES Uniq, GW15K-ETES G2 list unconfirmed for -ES-20

What do GoodWe error messages mean?

A GoodWe error is the inverter telling you what it noticed, such as no grid, too much backup load or poor insulation. GoodWe shows errors in the PV Master (SEMS) app, on the inverter display or in an alert email. Messages about leakage, insulation, ground, arcs or reversed polarity are safety issues and need a professional. GoodWe has two lists: a short older one for the ES Gen 1 and ET series, and a longer numbered one for the newer ES G2.

Model in SunTipid’s catalogList used on this pageJump to
GW5048D-ES (ES Gen 1)Short list from the ES manualsShort list
GW10K-ET (ET G2)Short list from the ET manualShort list
GW3000-ES-20 to GW6000-ES-20 (ES G2)Numbered list from the ES G2 manual (unconfirmed for these models)Numbered list
GW8000-ES (ES Uniq), GW15K-ETNot checkedUse the nearest list, with care

Which GoodWe models does this cover?

We used these GoodWe manuals: the ES manual for the GW3648D-ES and GW5048D-ES (two copies), the ET series manual, and the 2026 ES Series G2 manual for the US models. All these families appear in SunTipid’s GoodWe parts list. The manual for the GW3000 to GW6000-ES-20 models was not found, the ES Uniq (GW8000-ES) and the GW15K-ET manual were not checked, so treat those as unconfirmed.

Check your own manual. Messages and firmware vary by model and region. If your screen shows a message that is not here, we do not have an official meaning for it, so do not guess.

How do you restart a GoodWe inverter after an error?

This is the reset GoodWe’s manuals describe, and it uses only the external switches:

  1. Note the message, the time, and what was running.
  2. Switch off the AC output switch and the DC input switch.
  3. Wait 5 minutes. For over-temperature, one manual says to shut the inverter down for 15 minutes.
  4. Switch them back on and watch the display or app.

Do not open the inverter or touch the battery terminals. If the same message returns after one or two tries, stop and call your installer.

ES Gen 1 and ET messages (short list)

MessagePlain EnglishSafe owner-level checksCall your installer when
Utility LossThe inverter cannot detect the grid.Check whether Meralco power is out. Look at the AC breaker feeding the inverter: is it on? Wait for the grid to return. If all looks fine, GoodWe says to turn the AC breaker off and on again after 5 minutes.Power is on and the breaker is on, but it stays.
VAC FailureThe grid voltage is outside the range allowed for the safety country set in the inverter.Check whether other appliances show unusual voltage and wait a few minutes. Leave the safety country setting alone.It repeats. The manual’s safety-country, cable and voltage checks are for your installer.
FAC FailureThe grid frequency is outside the range allowed.Wait and watch. GoodWe says a few short occurrences are caused by occasional grid instability.It repeats often or the inverter will not restart.
Utility Phase Failure (ET only)The three phases of the grid connection are in the wrong order.Note the message. Do not touch wiring.Always. The manual says two phase cables are reversed, which is an installation fault.
Over TemperatureThe inverter is too hot.Check that nothing blocks the vents and the area is shaded and airy. GoodWe says to shut the inverter down for 15 minutes, then start it again.It returns, or the heat comes with a smell or discoloration.
Isolation FailureThe panel-side insulation looks poor, for example from damaged cable, aged panels or humidity.Note whether it appears mostly in the early morning or after rain. Do not touch cables or panels.It appears in dry midday weather or repeats. The manual’s checks use a multimeter.
Ground FailureGround leakage current is too high, often from a poor neutral or earth connection or humidity.Note the time of day. GoodWe says it may be normal if it happens only in early morning or rain and recovers soon.Always if it repeats. This is a grounding issue for a PEE.
Relay Check FailureThe inverter’s self-check of its relay failed. The manual links it to a poor neutral and ground connection on the AC side or an occasional glitch.Restart once, as the manual says.It returns. Involve a PEE.
DC Injection HighA high direct-current component in the AC output.Restart once and see if it comes back.It returns.
EEPROM R/W FailureAn internal memory fault, which the manual says can follow a strong external magnetic field.Restart once and see if it comes back.It returns.
SPI FailureAn internal communication fault, which the manual says can follow a strong external magnetic field.Restart once and see if it comes back.It returns.
DC Bus HighThe internal BUS voltage is too high.Restart once and see if it comes back.It returns.
PV/BAT Overvoltage (ET only)The panel or battery voltage is above the inverter’s limit.Switch off and call. Do not measure anything yourself.Always. The manual points to too many panels in series or too many battery packs.
Back-Up Over Load / Backup OverloadThe total load on the backup output is higher than its rated output.Reduce the loads on the backup output, then restart.It repeats with light loads.

Same list in the ES and ET manuals, except the two ET-only messages noted above. The ES manual calls the last one “Back-Up Over Load” and the ET manual “Backup Overload”.

Common symptoms with no code

These come from the troubleshooting pages of the ES and ET manuals.

Symptom, no codeES Gen 1 (GW3648D-ES, GW5048D-ES)ET series
Does not start with battery onlyThe battery voltage must be higher than 48 V, or the battery cannot start the inverter.The battery voltage must be higher than 180 V.
Does not start with solar onlyPV voltage must be above 150 V, and about 200 V to enter on-grid mode. Panel polarity must not be reversed.PV voltage must be above 180 V, and 230 V to enter on-grid mode. Panel polarity must not be reversed.
Battery does not dischargeLoad must be above 150 W, the smart meter and CT link must be working and the CT direction right. Battery also stops below its set depth of discharge, and during a set charge time.Same rules as ES: load above 150 W, working meter link, state of charge above the limit, and no charge period running.
Battery does not charge when solar exceeds the loadCheck the charge voltage and discharge time settings in the app and whether the battery is already full.Check the discharge time setting and whether the battery is already full.

ES G2 messages (numbered list)

The numbers are the manual’s own. Item 25 is not printed in the manual we used.

Grid

MessagePlain EnglishSafe owner-level checksCall your installer when
1 Utility LossThe grid is down, or the AC cable or breaker is off.The alarm clears by itself when the grid returns. Check the AC breaker is on.Power is on and the breaker is on, but it stays.
2 Grid Overvoltage, 3 Grid Rapid Overvoltage, 5 Grid 10min Overvoltage, 11 HVRT OvervoltageGrid voltage is too high, spiking, or high for too long.GoodWe says an occasional alarm may be a short grid event and the inverter recovers by itself. Wait.It happens often. Ask the utility. Protection limits may only be changed with the utility’s consent, by your installer.
4 Grid Undervoltage, 10 LVRT UndervoltageGrid voltage is too low or low for too long.Wait and watch. The inverter recovers by itself after a short grid event.It happens often. Ask the utility.
6 Grid Overfrequency, 7 Grid Underfrequency, 8 Grid Frequency InstabilityGrid frequency is outside the range, or changing too fast.Wait and watch. The inverter recovers by itself after a short grid event.It happens often.
9 Anti-islandingThe grid disconnected, but the loads kept the voltage up.Check whether the grid is actually off.It happens with the grid on.

Leakage, insulation and arcs

MessagePlain EnglishSafe owner-level checksCall your installer when
12, 13, 14, 15 Abnormal GFCI (30 mA, 60 mA, 150 mA)The insulation to ground dropped while the inverter was working.Note the time. If it was a one-off, GoodWe says the inverter may recover by itself. Do not touch cables.Always if it repeats. Leakage is a shock risk, so involve a PEE.
18 Low Insulation Res.The panel string may be shorted to ground, or the wiring is damp.Note whether it appears in rain. GoodWe says to reset the ISO if it is lower on rainy days. That reset is for your installer.It appears in dry weather or repeats.
19 Abnormal GroundThe inverter’s earth cable is not well connected, or line and neutral are swapped.Note the message. Do not touch wiring.Always. This is a grounding issue for a PEE.
27 DC Arc FaultA loose DC terminal or a broken DC cable.Switch off at the external switches and keep away from the panel wiring.Always. Arcs are a fire risk.

Solar panel input

MessagePlain EnglishSafe owner-level checksCall your installer when
31 PV Input OvervoltageToo many panels in series for the inverter.Switch off and call. Do not measure anything yourself.Always.
34 String1 PV String Reversed, 35 String2 PV String ReversedA panel string is connected the wrong way round.Switch off the DC switch and call right away.Always.
32, 33 PV Continuous Hardware or Software OvercurrentThe panel setup is not suitable, or hardware is damaged.Restart as described above.It returns.
30 BUS OvervoltageThe panel voltage is too high, or the inverter’s BUS reading is wrong.Restart as described above.It returns.

Temperature and internal

MessagePlain EnglishSafe owner-level checksCall your installer when
29 Cavity OvertemperatureThe inverter is poorly ventilated, the air is above 60 °C, or the internal fan failed.Check the vents are clear and the area is shaded and airy.It returns with good ventilation.
16, 17 Large DC of AC current L1 or L2The DC part of the AC output is out of range.If a grid event caused it, the inverter recovers by itself.It happens often.
20 Anti Reverse current protection for hardwaresThe load changed abnormally.Wait and see. The inverter recovers by itself if an outside event caused it.It happens often.
21 Internal Comm Loss, 22 AC HCT Check abnormal, 23 GFCI HCT Check abnormal, 24 Relay Check abnormal, 26 Flash Fault, 28 AFCI Self-check FaultInternal communication, sensing, relay, memory or arc-detection self-check faults.Restart as described above.It returns. Owners cannot repair these.

When should you call your installer or a PEE?

  • Call right away and keep the system off: any leakage, insulation, ground, arc or reversed-polarity message (for example Abnormal GFCI, Abnormal Ground, DC Arc Fault, String Reversed, Utility Phase Failure), or any smell of burning, smoke, heat damage, arcing sounds or water inside equipment.
  • Call your installer if it repeats: any message that returns after one or two restarts, or any message you do not recognise.
  • Involve a PEE: grounding, leakage, insulation or over-voltage problems, and any change to the system. Your installer’s warranty may depend on it.

When you call, have these ready, as GoodWe’s manual lists: the inverter serial number and software version, the installation date, when the fault happened and how often, the weather and any shading on the panels, and the utility grid situation. Need an installer? Find installers. Think the system was installed badly? Check our scam guide and Sulit ba? quote checker.

More fault-code guides

Frequently asked questions

What does a GoodWe error like Utility Loss or VAC Failure mean?

It is the message the inverter shows in the PV Master app, on its display or in an email alert when it detects a problem. Utility Loss means the inverter cannot see the grid, which is normal during a brownout. VAC Failure means the grid voltage is outside the range allowed. Find your message in the tables above for its meaning and the checks GoodWe suggests.

How do I restart a GoodWe inverter safely?

GoodWe’s manuals say to switch off the AC output switch and the DC input switch, wait 5 minutes, then switch them back on. For over-temperature, one manual says to shut the inverter down for 15 minutes first. Do not open the inverter. If the same message returns after a restart or two, call your installer.

Is it safe to keep using the system with an error showing?

Treat it as a warning and keep it simple. If the inverter has stopped, leave it off and call your installer. Never keep resetting a message that returns. Switch everything off and call an electrician right away if you smell burning, see smoke or discoloration, or hear arcing.

Why does my GoodWe show Utility Loss when Meralco is out?

Utility Loss means the inverter cannot detect the grid. During a Meralco outage that is expected, and GoodWe’s newer manual says the alarm clears by itself once grid power returns. If your power is on, check that the AC breaker feeding the inverter is on, then call your installer.

Why does my GoodWe show Isolation Failure or Low Insulation in the morning?

GoodWe says isolation and ground failures that appear only in the early morning or on rainy days, and recover soon, can be a normal effect of humidity. If it appears in dry midday weather or keeps returning, your installer or a PEE should check the panel wiring.

Which GoodWe models does this page cover?

We checked manuals for the ES Gen 1 (GW3648D-ES and GW5048D-ES), the ET series, and the ES G2 family. The ES G2 list comes from GoodWe’s US ES G2 manual, so it is unconfirmed for the GW3000 to GW6000-ES-20 models. The ES Uniq (GW8000-ES) and the GW15K-ET were not checked.

What if my message is not in this list?

GoodWe’s lists differ between series and firmware. If yours is not listed, write down the message, the model and serial number and the date and time, then send them to your installer. Do not guess.