Learning Center · Troubleshooting

Growatt Inverter Error Codes: What 201, 302, 408 and the Others Mean

A Growatt code is a message on the inverter screen. Error 302 means no AC connection (normal in a brownout), Error 408 means the inverter is too hot, and Bat Voltage Low means an almost empty battery. Messages about leakage, insulation, ground, arcs or reversed polarity (Errors 200, 201, 203, 303, 420) are safety issues: switch off at the external switches and call your installer. This guide covers the MIN, SPH and SPF families, with meanings from Growatt’s own manuals and the checks that are safe for an owner.

Updated November 23, 2026 · Codes checked against Growatt manuals November 23, 2026 · By the SunTipid team · Not engineering advice

Safety first: read the message, do the simple checks, and stop there. Never open the inverter, touch its terminals or cables, or work on the panels, battery or wiring yourself. Inverters carry dangerous voltage even when they look off. Anything beyond switching off, restarting and reading the display belongs to your installer or a licensed professional electrical engineer (PEE). This guide gives no wire sizes and no breaker ratings.
Families coveredMIN, SPH, SPFFrom 4 Growatt manuals
Safe restartAC breaker off, DC offWait for the display to go dark, then AC on, DC on
NeverOpen the inverterCall your installer or a PEE
Not checkedSPF 6000 ES PlusMIN 5000-6000TL-XH too

What do Growatt error codes mean?

A Growatt message is the inverter telling you what it noticed, such as no grid, too much load or leakage. Growatt uses different code schemes on different families, so first find which one you own, then read that section. Codes about leakage, insulation, ground, arcs or reversed polarity are safety issues and need a professional.

Family in SunTipid’s catalogTypical modelsCode styleJump to
MIN TL-X / TL-XH (grid-tie and hybrid)MIN 2500-6000TL-X2, MIN 3000-6000TL-XHError 2xx, 3xx, 4xx and Warning 2xx, 4xxMIN tables
SPH (hybrid)SPH 3000-6000Named messages plus some Error and Warning numbersSPH tables
SPF (off-grid)SPF 5000 ES, SPF 6000 ES PlusFault 01 to 81, Warning 01 to 45SPF tables

Which Growatt models does this cover?

We built this from four Growatt manuals: MIN 2500-6000TL-X, MIN 2500-4600TL-XH, SPH 3000-6000TL BL-UP and SPF 3500-5000 ES. All these families appear in SunTipid’s Growatt parts list. The MIN 5000 and 6000 TL-XH models, the SPF 6000 ES Plus and any other Growatt family (MOD, MAX and so on) were not checked, so treat their codes as unconfirmed.

Check your own manual. The same number can mean different things on different families. For example, Error 303 is “PE abnormal” on the MIN but “L N reversed or ground failed” on the SPH. If your screen shows a code that is not here, we do not have an official meaning for it, so do not guess.

How do you restart a Growatt inverter after an error?

This is the shutdown and start-up order in Growatt’s MIN manual. It uses only the external switches:

  1. Note the code, the time, and what was running.
  2. Switch off the AC breaker, then the DC switch.
  3. Wait until the lights and display go out.
  4. Switch the AC breaker on, then the DC switch. The manual says the inverter then starts by itself once the panel voltage is high enough.

Never unplug DC connectors while the inverter is running, since Growatt’s manual lists it as a danger. Do not open the inverter. If the same code returns after one or two tries, stop and call your installer. The SPH manual also says covers may only be removed by a professional with the whole system off.

MIN TL-X and TL-XH codes (grid-tie and hybrid)

System errors: mostly caused by the grid or the panels

CodeWhat the manual calls itPlain EnglishSafe owner-level checksCall your installer when
Error 302No AC connectionThe inverter cannot see the grid.Check whether Meralco power is out. Look at the AC breaker feeding the inverter: is it on? Wait for the grid to return.Power is on and the AC breaker is on, but the code stays.
Error 300AC V OutrangeThe grid voltage is outside the range allowed.Check whether other appliances show low or unstable voltage. Wait, then restart as described above.It repeats, or other appliances misbehave. The manual says to check AC wiring and ask Growatt.
Error 304AC F OutrangeThe grid frequency is outside the range allowed.Wait and watch, then restart as described above. This is mostly a grid condition.It repeats, or the inverter will not restart.
Error 303PE abnormalThe neutral and ground (PE) wires differ by more than 30 V.Note the code. Do not touch any wiring.Always. This is a grounding and wiring issue for your installer or a PEE.
Error 201Residual I HighLeakage current is too high.Restart once, as the manual says.It returns. Leakage is a shock risk, so involve a PEE.
Error 203PV Isolation LowThe insulation on the panel side looks poor, for example from damaged cable or moisture.Note whether it appears mostly in rain or morning dew. Do not touch cables, the panels or the DC breaker.Always. The manual’s checks involve ground, wiring and meter readings.
Error 202PV Voltage HighThe DC voltage from the panels is above what the inverter allows.The manual says to switch off the DC switch at once. Then call your installer. Do not measure anything yourself.Always, right away.
Error 407Auto Test FailedA start-up auto test did not pass.Restart, as the manual says.It returns. The manual gives no further detail.

Inverter faults and warnings

CodeWhat the manual calls itPlain EnglishSafe owner-level checksCall your installer when
Error 200AFCI faultThe inverter suspects an electrical arc on the panel wiring.Switch off the DC switch and keep away from the panel wiring.Always. Arcs are a fire risk.
Error 425AFCI self-test faultThe arc-detection self-test failed.Restart once.It returns.
Error 420GFCI faultThe ground-leakage protection tripped.Restart once.It returns. Involve a PEE.
Error 408Over TemperatureThe inverter is too hot.Check that nothing blocks the vents and the area is shaded and airy. The manual says to restart only if the ambient temperature is below 60 °C.It returns, or the heat comes with a smell or discoloration.
Error 402Output High DCIToo much direct current on the AC output.Restart once.It returns.
Errors 404, 405, 409, 411, 414, 417Bus sample fault, Relay fault, Bus over voltage, DSP communicates with M3 abnormal, EEPROM fault, sampled data mismatchInternal faults inside the inverter.Restart once, as the manual says for each.Any of them returns. Owners cannot repair these.
CodeWhat the manual calls itPlain EnglishSafe owner-level checksCall your installer when
Warning 401Inverter communicates with meter abnormalThe inverter lost contact with its smart meter.Check that the meter is powered on. The manual’s second check (connection) is for your installer.The meter is on and the warning stays.
Warning 203PV1 or PV2 circuit shortA panel input circuit may be shorted.Do not open anything. Note the code.Always. The manual points to checking panel polarity.
Warning 205PV1 or PV2 boost brokenAn internal panel-input component problem.Restart once.It returns. Growatt service may need to replace a board.
Warning 204Dryconnect function abnormalThe dry-contact signal port is faulty.Note the code.It stays. Wiring check needed.
Warning 202DC SPD function abnormalThe DC surge protector is abnormal (listed in the MIN TL-X manual only).Note the code.Always. The manual says to check the SPD after shutdown.
Warning 207USB over-currentThe USB port is drawing too much.Switch off first, then unplug the USB stick or monitoring dongle. Reconnect only after shutdown.It returns with nothing plugged in.
Warnings 404 and 405EEPROM abnormal; Firmware version not consistentInternal memory or firmware mismatch.Restart once.It returns. A firmware update may be needed.

The MIN TL-X and TL-XH manuals list the same errors and warnings, except that Warning 202 appears only in the TL-X manual.

SPH codes (hybrid)

The SPH shows many messages by name instead of by number. We keep the manual’s wording so you can match the screen.

Grid and meter

CodeWhat the manual calls itPlain EnglishSafe owner-level checksCall your installer when
No AC ConnectionNo utilityThe inverter cannot see the grid.Check whether Meralco power is out. Check that the switches on the cable to the inverter are on.Power is on and the switches are on, but the message stays.
AC V OutrangeGrid voltage faultThe grid voltage is outside the allowed range.Check whether other appliances also show low voltage. Wait a few minutes.It repeats often.
AC F OutrangeGrid frequency faultThe grid frequency is outside the allowed range.Wait and watch. The manual says to restart the inverter if needed.It stays after a restart.
Warning 401SP-CT/Meter communication faultThe inverter lost its link to the meter or current sensor.Restart the inverter once.It returns. The manual’s wire and distance checks are for your installer.
PairingTimeOutCommunication faultPairing with the SP-CT failed.Restart once.It stays.
CT LN ReversedLN reversedThe line and neutral of the sensor are reversed.Note the message. Do not touch wiring.Always. This is an installation matter.
Error 303Inverter L N reversed or ground failedLine and neutral swapped, or the ground connection is faulty.Note the code. Do not touch wiring.Always, with a PEE.
Output High DCIOutput DC current too highToo much direct current on the AC output.Restart once.It returns.

Battery and BMS

CodeWhat the manual calls itPlain EnglishSafe owner-level checksCall your installer when
Bat Voltage LowBattery voltage lower than 42 VThe battery is almost empty.Check the charge level on the battery’s own display. Reduce loads and let solar or the grid recharge it.It does not recharge.
Bat Voltage HighBattery voltage higher than 60 VThe battery voltage is too high.Turn the system off with the external switches and call. Do not touch battery cables.Always.
Battery reversedBattery terminals reversedThe battery is connected the wrong way round.Switch off and call right away.Always. Reversed polarity is a fire risk.
Battery OpenBattery terminal open (lithium only)The inverter cannot see the lithium battery.Check that the battery and the switches between it and the inverter are all on.They are on and it stays.
BAT NTC OpenBattery temperature sensor open (lead-acid only)The lead-acid battery’s temperature sensor is missing or disconnected.Note the message.Always.
BMS COM FaultCommunication faultThe inverter lost its data link to a lithium battery.Check that the lithium battery is switched on.It stays. The cable checks are for your installer.
BMS Warning:XXX / BMS error:XXXBMS reports a warning or errorThe battery’s own management system reports a problem; the XXX is the battery’s code.Read the battery’s user manual for the XXX code. Note it.It stays after a restart.
Warning 506Battery temperature out of range for charge or dischargeThe battery is too hot or too cold.Check that the room or battery area is within the battery’s temperature range.It stays after the temperature is fine.

Backup (EPS) output

CodeWhat the manual calls itPlain EnglishSafe owner-level checksCall your installer when
Over LoadEPS output overload warningThe backup output has too much load. If it happens three times, off-grid output is locked for one hour.Reduce the load on the backup output.It repeats with light loads.
EPS Volt LowEPS output voltage lowThe backup output voltage is low, often from overload.Reduce the load and restart.It stays.
OP Short Fault!EPS output short faultA short on the backup output.Switch off and note the code. Do not trace wiring.Always.

Solar panels

CodeWhat the manual calls itPlain EnglishSafe owner-level checksCall your installer when
PV Isolation LowPV isolation too lowThe panel-side insulation looks poor.Note whether it appears mostly in rain or dew. Do not touch cables.Always.
Warning 203PV1 or PV2 circuit shortA panel input circuit may be shorted or reversed.Do not open anything. Note the code.Always. The manual says to check PV positive and negative.
PV Voltage HighPV voltage higher than datasheetThe panel voltage is above the inverter’s limit.Switch off the DC switch and call.Always.
Residual I HighLeakage current too highLeakage current is too high.Restart once, as the manual says.It returns. Shock risk: involve a PEE.

Internal and setup

CodeWhat the manual calls itPlain EnglishSafe owner-level checksCall your installer when
Error 408Temperature over rangeThe inverter temperature is out of range.Check that nothing blocks the vents and the area is shaded and airy.It returns.
NTC OpenInternal temperature failedAn internal temperature sensor failed.Note the code.Always, since the manual says to contact the service center.
Errors 405, 411, 417Relay fault; internal communication failed; sample faultInternal faults inside the inverter.Restart once.Any returns.
Error 418DSP and COM firmware unmatchThe inverter’s two firmware parts do not match.Note the code.Always. Firmware must be updated by a professional.
Error 406Model set up not meet certificationThe model or DIP setting does not match the grid certification.Note the code.Always. Settings are for your installer.
Error 123Autotest failed (Italy only)A grid-code self-test applies only in Italy.Note the code.If you see it in the Philippines, tell your installer.

SPF codes (off-grid)

Growatt’s SPF manual lists what each code means but gives no suggested fix, so the “safe checks” below are SunTipid’s general advice, not manual text. The SPF 6000 ES Plus has its own manual, which we did not check.

Faults

CodeWhat the manual calls itPlain English and safe checks
Fault 01, 02Fan is locked; Over temperatureCooling problem. Check the vents are clear and the area is shaded and airy. Switch off and call if it repeats.
Fault 03, 04, 56Battery voltage too high; too low; battery connection openCheck the battery’s own display and that its isolator is on. Do not touch battery cables. Call if it stays.
Fault 05, 07, 51Output short circuited; Overload time out; Over current or surgeSwitch off big loads and restart once. If it returns with light loads, call.
Fault 06, 58, 55Output voltage too high; too low; Over DC voltage in AC outputAn output-side problem inside the inverter. Restart once and call if it returns.
Fault 08, 09, 52, 53Bus voltage too high; Bus soft start failed; Bus voltage too low; Inverter soft start failedInternal power-stage faults. Restart once and call if it returns.
Fault 57, 60, 62, 80, 81Current sensor failed; Negative power fault; Internal communication error; CAN fault; Host lossInternal sensor or communication faults. For 80 and 81, the CAN and host links to a battery or parallel unit are for your installer.
Fault 61PV voltage is too highPanel voltage above the limit. Switch off the PV isolator if there is one and call.

Warnings

CodeWhat the manual calls itPlain English and safe checks
Warning 01, 02Fan locked when inverter is on; Over temperatureSame as fault 01 and 02: check ventilation.
Warning 03, 04, 19Battery over-charged; Low battery; Battery disconnectLook at the battery display and recharge. Check its isolator is on.
Warning 07, 10Overload; Output power deratingReduce loads. Derating means the inverter is cutting output, often from heat.
Warning 12, 13, 14, 21Solar charger stops (low battery, high PV voltage, overload); PV power insufficientUsually clouds, dusk or heavy loads. Wait and reduce loads.
Warning 15, 16, 17, 22, 25Parallel-system warningsOnly if two or more units are wired together. Call your installer.
Warning 18Buck over currentAn internal charger current limit. Call if it repeats.
Warning 20, 33BMS communication error; BMS communication lossThe data link to a lithium battery failed. Check the battery is on; call if it stays.
Warning 34 to 45Cell over or under voltage, total over or under voltage, discharge or charge over voltage or over temperature, MOSFET and battery over or under temperature, system shut downThe battery’s own protection is reporting. Read the battery’s manual and call your installer if it stays.

When should you call your installer or a PEE?

  • Call right away and keep the system off: any leakage, insulation, ground, arc or reversed-polarity message (for example Error 200, 201, 203, 303, 420, PV Isolation Low, Battery reversed), or any smell of burning, smoke, heat damage, arcing sounds or water inside equipment.
  • Call your installer if it repeats: any code that returns after one or two restarts, or any code you do not recognise.
  • Involve a PEE: grounding, leakage, insulation or over-voltage problems, and any change to the system. Your installer’s warranty may depend on it.
  • Warranty note: Growatt’s SPH warranty excludes damage from unauthorized modification or attempted repairs. Do not open it.

When you call, have these ready, as Growatt’s manuals list: model and serial number, the message on the display, a short description of the problem, the grid voltage and DC input voltage if known, whether it can be repeated, and whether it happened before. Need an installer? Find installers. Think the system was installed badly? Check our scam guide and Sulit ba? quote checker.

More fault-code guides

Frequently asked questions

What does a Growatt error code like 201, 302 or 408 mean?

It is the number the inverter shows on its screen when it detects a problem. Error 302 means no AC connection, error 201 means leakage current too high, and error 408 means over-temperature. Find your number in the tables above. The same number can mean different things on different Growatt families, so check the family you own first.

What is the difference between an Error and a Warning on a Growatt?

Growatt’s manuals separate them. A warning flags something the inverter can keep running through, such as a lost meter link. An error or fault means the inverter has stopped or cannot work normally. In both cases write the code down before you reset anything.

How do I restart a Growatt inverter safely?

Growatt’s MIN manual says to switch off the AC breaker and the DC switch, then wait until the lights and display go out. To start again, switch the AC breaker on and then the DC switch on, and the inverter starts by itself once the panel voltage is high enough. Never unplug DC connectors while the inverter is running, since the manual warns against it.

Is it safe to keep using the system with an error showing?

Treat it as a warning to keep things simple. If the inverter has stopped, leave it off and call your installer. Never keep resetting a code that returns. Switch everything off and call an electrician right away if you smell burning, see smoke or discoloration, or hear arcing.

Why does my Growatt show error 302 or ‘No AC connection’?

The inverter cannot see the grid. During a Meralco outage that is expected, and it should clear when power returns. If your power is on, check that the AC breaker feeding the inverter is on, then call your installer.

What do the Growatt SPF error codes like 01 to 81 mean?

The SPF off-grid models use a separate two-digit scheme. Fault 01 is a locked fan, 03 and 04 are battery voltage too high or too low, and 07 is an overload time-out. The SPF section of this page lists the codes printed in Growatt’s manual.

What if my code is not in this list?

Growatt’s codes differ between product families and firmware. This page covers the codes printed in the four manuals we checked. If yours is not listed, write down the code, the model and serial number and the date and time, then send them to your installer. Do not guess.

Planning a Growatt build?

See which Growatt models fit your bill and how many panels they accept.

See Growatt invertersOpen the Builder

Sources and last checked

Checked November 23, 2026. SunTipid is not a law firm or an engineering firm. This is general information, not legal or engineering advice. Meanings and checks are paraphrased from the manuals above in our own words. Always follow the manual that came with your inverter.