Solis Inverter Alarm Codes: What NO-Grid, OV-G-V01, ILeak-PRO and the Others Mean

A Solis message is shown on the inverter screen or in the SolisCloud app. NO-Grid means the inverter cannot see the grid (normal in a brownout), OV-TEM means it is too hot, and UN-Vbatt means a low battery. Alarms about leakage, insulation, ground, arcs or reversed polarity (ILeak-PRO, ARC-FAULT, Reve-DC) are safety issues: switch off at the external switches and call your installer. This guide covers the S6 hybrid and grid-tie models, with meanings from Solis’s own manuals and alarm list, and the checks that are safe for an owner.

Updated November 23, 2026 · Messages checked against Solis sources November 23, 2026 · By the SunTipid team · Not engineering advice

Safety first: read the message, do the simple checks, and stop there. Never open the inverter, touch its terminals or cables, or work on the panels, battery or wiring yourself. Inverters carry dangerous voltage even when they look off. Solis itself says only trained electricians should diagnose and repair a system. Anything beyond switching off, restarting and reading the display belongs to your installer or a licensed professional electrical engineer (PEE). This guide gives no wire sizes and no breaker ratings.
Models coveredS6-EH1P hybrid, S6-GR1PFrom Solis manuals and its alarm list
Safe power-offAC, then DC, then batteryTurn on in reverse: battery, DC, AC
NeverOpen the inverterCall your installer or a PEE
Not checkedS6-EH1P10K, S6-GR1P manualMarked unconfirmed

What do Solis alarm messages mean?

A Solis message is the inverter telling you what it noticed, such as no grid, a battery problem or too much load. Solis shows three kinds: operating status (normal), warnings and alarms. Alarms about leakage, insulation, ground, arcs or reversed polarity are safety issues and need a professional.

Model in SunTipid’s catalogTypeWhere this page gets the listJump to
S6-EH1P3K to 10K-L-PLUSHybrid (battery and backup)Solis S6 hybrid manualsHybrid tables
S6-GR1P5KGrid-tie (no battery)Solis alarm list from its support siteGrid-tie tables

Which Solis models does this cover?

For the hybrid models we used three Solis S6 hybrid manuals (S6-EH1P8K-L-PLUS, S6-EH1P(3-6)K-L and RHI(3-6)K-S6). They print the same message list. For the grid-tie S6-GR1P we used Solis’s own online alarm list, since we did not find a model manual with a readable table. Both appear in SunTipid’s Solis parts list. The S6-EH1P10K-L-PLUS was not separately checked and the S6-GR1P manual itself was not checked, so treat them as unconfirmed. Solis’s three-phase and larger models are not covered.

Check your own manual. Messages and firmware vary by model and region. If your screen shows a message that is not here, we do not have an official meaning for it, so do not guess. Some Solis alarms also show a code number, which we list for the grid-tie models.

How do you restart a Solis hybrid inverter after an alarm?

This is the order in Solis’s S6 hybrid manual. It uses only the external switches:

  1. Note the message, the time, and what was running.
  2. Turn off the AC breaker, then the inverter’s DC switch, then the battery breaker. Checking that voltages have dropped to zero is a job for an electrician.
  3. Wait a few minutes.
  4. Turn the battery on, then the DC switch, then the AC breaker.

Do not open the inverter. If the same alarm returns after one or two tries, stop and call your installer. Solis says the S6 can power on from solar, battery or grid alone, so it may start even if only one source is present.

S6-EH1P hybrid messages

Operating status messages (not faults)

MessageWhat the manual calls itPlain EnglishSafe owner-level checksCall your installer when
OffControl device to shutdownThe inverter has been switched off from its settings.Turn it on in the ON/OFF setting if you switched it off.It switches itself off.
LmtByEPMOutput is under controlAn export limit or meter is capping the inverter’s output.Nothing to fix if you set an export limit on purpose.You did not set a limit and output stays low.
LmtByDRM, LmtByTemp, LmtByFreq, LmtByUnFrDRM on; over-temperature, frequency or under-frequency power limitThe inverter is trimming its output for a rule, heat or grid frequency.The manual says no action is needed. Check ventilation if it is LmtByTemp.It limits output often.
LmtByVg, LmtByVarVolt-Watt or Volt-Var modeA grid-code mode that trims output when grid voltage is high.The manual says this generally needs no action.Output drops often and you want the setting reviewed.
Standby, StandbySynoch, GridToLoadBypass run; off-grid to on-grid; grid to loadNormal operating states.None. The manual says no action is needed.Not a fault.

Grid

MessageWhat the manual calls itPlain EnglishSafe owner-level checksCall your installer when
NO-GridNo gridThe inverter cannot see the grid.Check whether Meralco power is out. Look at the AC breaker feeding the inverter: is it on? Wait for the grid to return.Power is on and the AC breaker is on, but it stays.
OV-G-V01, V04, V03, UN-G-V01, UN-G-V02Grid voltage above or below the allowed rangeThe grid voltage is too high or too low for the inverter.Check whether other appliances show unusual voltage. Wait, then restart the system once.It repeats often. Ask Meralco about the voltage.
OV-G-V02, OV-G-V05, IGFOL-FTransient grid overvoltage; RMS overvoltage; grid current tracking failureA short grid spike or a tracking error.Restart the system once, as the manual says.It returns.
OV-G-F01, OV-G-F02, UN-G-F01, UN-G-F02Grid frequency above or below rangeThe grid frequency is outside the allowed range.Wait and watch, then restart once. Mostly a grid condition.It repeats, or the inverter will not restart.
G-PHASE, G-F-GLUUnbalanced grid voltage; grid frequency fluctuationThe grid is unbalanced or unsteady.Wait and restart once.It repeats.
Surge AlarmOn-site grid surgeThe grid had a surge.Restart the device once.It stays after a restart.

Battery and backup output

MessageWhat the manual calls itPlain EnglishSafe owner-level checksCall your installer when
NO-BatteryBattery is not connectedThe inverter cannot see the battery.Check that the battery is switched on and its breaker is on. Read the battery voltage on the inverter’s info page. Measuring at the plug is for your installer.It stays.
BatName-FAILWrong battery brand selectionThe battery model set in the inverter does not match the real battery.Note the message. Do not change settings yourself.Always. The setting is for your installer.
CAN FailCommunication with the battery failedThe inverter lost its data link to the battery.Check that the battery is on. The cable and port checks are for your installer.It stays. Some batteries need a special cable.
OV-VbattBattery overvoltageThe battery voltage is too high.Switch the system off with the external switches and call. Do not touch battery cables.Always.
UN-VbattBattery undervoltageThe battery voltage is too low.Restart once, as the manual says. Check the charge level and recharge.It stays.
OV-Vbatt-H / OV-BUS-HBattery overvoltage hardware failure / VBUSA hardware overvoltage trip.Check whether the battery breaker has tripped. Do not reset it more than once.Always. The manual also says to check if the battery is damaged.
OV-VbackupInverting overvoltageThe backup output voltage is too high.Restart the system once.It stays. The manual’s wiring check is for your installer.
Over-LoadLoad overload faultThe backup load is too large, or an inductive load such as a motor starts too hard.Remove some backup loads and any large inductive load, then restart.It repeats with light loads.

Solar panels and leakage

MessageWhat the manual calls itPlain EnglishSafe owner-level checksCall your installer when
OV-DC01, OV-DC02DC 1 or DC 2 input overvoltageThe panel voltage is too high.Switch off the DC switch and call. Do not measure anything yourself.Always.
DC-INTF.Abnormal DC input currentThe DC input current looks abnormal.Do not touch cables. Note the message.Always. The manual points to loose DC connections.
OV-DCA-I, OV-DCB-IDC 1 or DC 2 average overcurrentToo much DC current on a panel input.Restart once, as the manual says.It returns.
PV ISO-PRO01, PV ISO-PRO02PV negative or positive ground faultThe panel wiring may be leaking to ground, from damaged cable or moisture.Note the time. Do not touch cables or panels.Always, if it appears in dry weather or repeats.
ILeak-PRO01 to 04, ILeak_CheckLeakage current failures (30 mA, 60 mA, 150 mA and more) and sensor failureLeakage current to ground was detected.Restart once. Do not touch anything.Always. Leakage is a shock risk, so involve a PEE.

Temperature and internal

MessageWhat the manual calls itPlain EnglishSafe owner-level checksCall your installer when
OV-TEMModule over temperatureThe inverter is too hot.Check that nothing blocks the vents and the area is shaded and airy.It returns, or the heat comes with a smell or discoloration.
UN-TEMLow temperature protectionThe inverter is too cold.Check the working environment temperature, then restart once.It stays in normal weather.
Fan AlarmFan alarmThe internal fan may be jammed or not working.Look and listen from outside. Do not open the case.It stays.
OV-BUS, UN-BUS01, UN-BUS02, UNB-BUSDC bus overvoltage, undervoltage, abnormal detection or unbalanceInternal power-stage voltage faults.Restart once.It returns.
OV-G-I, GRID-INTF., GRID-INTF02, DCInj-FAULTAC overcurrent or grid disturbance; DC component above limitThe grid or AC side looks abnormal.Check whether the grid is acting up and the AC breaker is on, then restart once.It returns. The manual’s cable checks are for your installer.
RelayChk-FAIL, IGBT-OV-I, 12Power-FAULTRelay failure; IGBT overcurrent; 12 V undervoltageInternal faults.Restart once.Any returns.

S6-GR1P grid-tie alarms

These come from Solis’s own online alarm list, which says only trained electricians should diagnose and repair. The numbers in brackets are Solis’s alarm codes.

Grid and meter

MessageWhat the manual calls itPlain EnglishSafe owner-level checksCall your installer when
NO-Grid (1015)No gridThe inverter cannot see the grid.Check whether Meralco power is out and the AC breaker is on.Power is on and the breaker is on, but it stays.
OV-G-V (1010), UN-G-V (1011), OV-G-F (1012), UN-G-F (1013)Grid voltage or frequency out of rangeThe grid is above or below the allowed range.Solis says an occasional alarm may be a short grid event and the inverter resumes by itself. Wait.It happens often. Solis may need to adjust limits with the utility’s approval.
G-PHASE (1016), G-F-FLU (1017), OV-G-I (1018), PHASE-FAULT (101A)Unbalanced grid, unstable frequency, grid overcurrent, abnormal phase angleA grid-side problem.Check whether the grid is acting up, then restart once.It repeats. Wiring checks are for your installer.
Backfeed_Iac (1014), IGFOL-F (1019), INI-FAULT (1031), IG-AD (1047), Vg-Sample (1059)AC backfeed current, current tracking error, DSP initializing fault, sampling errorsControl or sensing errors inside the inverter.Restart once.It returns.
GRID-INTF. (1030)Grid interferenceThe grid waveform is noisy, for example with several inverters on one line.Restart once.It repeats. A filter setting may help, which is for your installer.
Failsafe (2010)EPM communication failThe inverter lost its link to the export meter.Check that the meter is powered on.It stays.

Solar panels, leakage and arcs

MessageWhat the manual calls itPlain EnglishSafe owner-level checksCall your installer when
OV-DC (1020), BoostFal (1020), OV-BUS (1021), UNB-BUS (1022), UN-BUS (1023), Vbus-Sam (102A)DC overvoltage, boost circuit fault, bus voltage faultsThe panel or internal DC voltages are abnormal.Restart once. Do not measure anything yourself.It returns. Overvoltage needs a technician.
DC-INTF. (1027)Abnormal DC input currentThe DC current looks abnormal.Do not touch cables. Note the message.Always. Solis points to loose or damaged DC wiring.
Reve-DC (1028)DC reversely connectedA panel string is connected the wrong way round.Switch off the DC switch and call right away.Always. Reversed polarity is a fire risk.
PV ISO-PRO01 and 02 (1033), PvMidIso (1029), PVGndRun (1029)Low PV insulation; PV grounded while runningThe panel wiring may be leaking to ground.Solis says alarms in early morning, late afternoon or rain are often normal moisture effects. Note the time.It appears in dry midday weather or keeps returning.
ILeak-PRO (1034), ILeak-Check (1039), L&PE FAULT (F017)Leakage current protection; self-check; low resistance between L and PELeakage to ground was detected.Restart once. Do not touch anything.Always. Leakage is a shock risk, so involve a PEE.
ARC- FAULT (1041), AFCI-Check (1040)DC arc detected; AFCI self-checkThe inverter suspects an arc in the DC wiring.Switch off the DC switch and keep away from panel wiring.Always. Arcs are a fire risk.

Temperature and internal

MessageWhat the manual calls itPlain EnglishSafe owner-level checksCall your installer when
OV-TEM (1032)Over temperature near the IGBTsThe inverter is too hot.Check for direct sun, blocked vents and a loose mounting. Solis says to turn the inverter off and restart after 15 minutes.It returns.
UN-TEM (103A)Low temperatureThe inverter is too cold.Check the ambient temperature, then restart once.It stays in normal weather.
RelayChk-FAIL (1035), DSP-B-FAULT (1036), DCInj-FAULT (1037), 12Power-FAULT (1038), IGBT-OV-I (1048)Relay, DSP, DC injection, 12 V supply and IGBT faultsInternal faults.Restart once.Any returns.
DSP-SelfCheck (1058)DSP firmware does not match the hardwareA firmware mismatch.Note the message.Always. Firmware is for your installer.

Warnings

MessageWhat the manual calls itPlain EnglishSafe owner-level checksCall your installer when
Fan Alarm, Fan_H AlarmInternal or external fan faultA fan may be stuck.Look and listen from outside. Do not open the case.It stays.
DcSpdFail, VgSpdFailDC or AC surge protector faultA surge protector failed.Restart once.It stays.
FuseFailFuse alarm (some models)A fuse alarm on larger models.Note the message.Always.
Surge AlarmGrid has surgeA grid surge was recorded. Solis says it does not affect operation.None.Not a fault.

When should you call your installer or a PEE?

  • Call right away and keep the system off: any leakage, insulation, ground, arc or reversed-polarity message (for example ILeak-PRO, PV ISO-PRO in dry weather, ARC-FAULT, Reve-DC, OV-Vbatt), or any smell of burning, smoke, heat damage, arcing sounds or water inside equipment.
  • Call your installer if it repeats: any alarm that returns after one or two restarts, or any message you do not recognise.
  • Involve a PEE: grounding, leakage, insulation or over-voltage problems, and any change to the system. Your installer’s warranty may depend on it.

When you call, have these ready: model and serial number, the exact message and code, the time it started, what was running, and whether it clears by itself. Need an installer? Find installers. Think the system was installed badly? Check our scam guide and Sulit ba? quote checker.

More fault-code guides

Frequently asked questions

What does a Solis alarm like NO-Grid or OV-G-V01 mean?

It is the message the inverter shows on its screen or in the SolisCloud app when it detects a problem. NO-Grid means the inverter cannot see the grid, which is normal during a brownout. OV-G-V01 means the grid voltage is higher than the allowed limit. Find your message in the tables above for its meaning and the checks Solis suggests.

Are messages like LmtByEPM or Standby faults?

No. Solis lists them as operating status messages. They tell you what the inverter is doing, for example limiting its output or waiting. The manual says most of them need no action.

How do I restart a Solis hybrid inverter safely?

Solis’s S6 hybrid manual gives the power-off order: turn off the AC breaker, turn off the inverter’s DC switch, then turn off the battery breaker. To power on, turn the battery on, then the DC switch, then the AC breaker. Checking voltages with a meter is for an electrician. Do not open the inverter.

Is it safe to keep using the system with an alarm showing?

Treat it as a warning and keep it simple. If the inverter has stopped, leave it off and call your installer. Never keep resetting an alarm that returns. Switch everything off and call an electrician right away if you smell burning, see smoke or discoloration, or hear arcing.

Why does my Solis show PV ISO-PRO01 in the morning or after rain?

Solis says low insulation alarms that appear early in the morning, late in the afternoon or on rainy days are often a normal result of moisture in the air. If it appears in dry midday weather or keeps returning, have your installer or a PEE check the panel wiring.

What is the difference between the S6-EH1P and S6-GR1P?

The S6-EH1P is a hybrid inverter with a battery port and a backup output. The S6-GR1P is a grid-tie inverter without a battery. Their alarm lists overlap but are not identical, so use the section for your model.

What if my message is not in this list?

Solis’s lists differ between model families and firmware. This page covers the messages printed in the manuals and Solis’s own alarm list that we checked. If yours is not listed, write down the message, the model and serial number and the date and time, then send them to your installer. Do not guess.

Planning a Solis build?

See which Solis models fit your bill and how many panels they accept.

See Solis invertersOpen the Builder

Sources and last checked

Checked November 23, 2026. SunTipid is not a law firm or an engineering firm. This is general information, not legal or engineering advice. Meanings and checks are paraphrased from the sources above in our own words. Always follow the manual that came with your inverter.