SunTipid expansion tool · 2026 PH street prices
Solar Battery Upgrade and Runtime Calculator
How much battery do I need to run an aircon overnight? For one 1 HP inverter aircon, a fridge and fans (about 0.8 kW) for 10 hours, you need about 10.6 kWh of nominal LiFePO4 capacity, which is 8.00 kWh of energy divided by 0.94 inverter efficiency and 0.80 usable capacity (80% depth of discharge, to protect battery life). In practice that is 1 × 14.33 kWh, about ₱81,500 to ₱87,000 at November 23, 2026 street prices. Change the inputs to see your number.
How much battery should I add?
12+ hours is calculated as 12 hours.
Runtime uses ~94% inverter efficiency and 80% usable capacity in one factor (0.752), so the same loss is never counted twice. We size batteries on 80% usable capacity to protect battery life and cycle count; your inverter may allow more. Solar recharge uses 4.2 peak sun hours and 80% system efficiency, typical Philippine figures.
48 V LiFePO4 packs in the SunTipid catalog
Street prices run from the cheapest model to the 75th percentile of each size, as of November 23, 2026. The calculator picks the cheapest combination of these packs that covers your need.
| Pack size | Models | Street price | Runtime with your inputs | Cheapest example |
|---|---|---|---|---|
| 5.12 kWh pack | 11 | ₱33,000 to ₱42,000 | 4.8 h | Generic rack 51.2V 100Ah LiFePO4 rack |
| 6.14 kWh pack | 1 | ₱56,000 to ₱56,000 | 5.8 h | Deye RW-M6.1-B (6.14kWh) |
| 10.24 kWh pack | 5 | ₱58,000 to ₱82,000 | 9.6 h | Generic wall 51.2V 200Ah LiFePO4 wall |
| 14.33 kWh pack | 2 | ₱78,000 to ₱78,000 | 13.5 h | EVE cells (DIY kit) 51.2V 280Ah LiFePO4 kit |
| 15.36 kWh pack | 1 | ₱88,000 to ₱88,000 | 14.4 h | Lvtopsun LVTS-512300-G3 (15.36kWh) |
| 16.08 kWh pack | 4 | ₱85,000 to ₱108,000 | 15.1 h | Seplos Mason 314L (16.08kWh) |
Prices are warehouse cash street prices excluding delivery and installation. High-voltage and stack batteries are not included because they need a matching hybrid inverter.
How the math works
- Target energy (kWh) = total hourly load (kW) × target hours.
- Required nominal capacity = target energy ÷ (0.94 × 0.80). This covers about 94% inverter efficiency and 80% usable capacity once. We use 80% to protect battery life and cycle count; your inverter may allow more.
- Additional capacity needed = the larger of 0 and required nominal capacity minus your existing battery.
- Solar recharge check = array kWp × 4.2 sun hours × 0.80, compared with the kWh you need to refill.
Appliance wattages are typical eco-mode averages. Compressor start-up surges are higher, so confirm your inverter’s surge rating with a PEE.
Battery upgrade FAQ
How many kWh of battery do I need to run an aircon overnight?
A 1 HP inverter aircon in eco mode averages about 550 W, so 10 hours is 5.5 kWh of energy. Divide by 0.94 inverter efficiency and 0.80 usable capacity (we use 80% to protect battery life) and you need about 7.3 kWh of nominal battery for the aircon alone. Add a fridge and fans and it is about 10.6 kWh.
How long will a 5.12 kWh battery run a 1 HP inverter aircon?
About 7.0 hours on the aircon alone at 550 W, and about 4.8 hours with a fridge and fans added (800 W total), after inverter losses and 80% usable capacity. Real runtime depends on room size, temperature and how hard the compressor works.
Can I add a battery to an on-grid solar system?
Not directly. A grid-tie string inverter cannot charge a battery. You either replace it with a hybrid inverter (hardware about ₱29,500 to ₱46,000 for a 5 to 6 kW 48 V model, plus labor) or add an AC-coupled battery inverter. A PEE can tell you which suits your system.
Can I connect more battery packs in parallel?
Usually yes, if the packs are the same voltage and chemistry, but each model has a parallel limit set by its BMS, and every pack needs proper fusing and a busbar. Mixing brands or old and new packs is not recommended without checking the datasheets. Have a PEE design the bank.
What is the 0.5C limit on a battery?
C-rate is charge or discharge current relative to capacity. Many 51.2 V 100 Ah packs are rated for about 0.5C continuous, roughly 50 A, though the exact figure is on the datasheet. Adding packs in parallel raises the total current the bank can supply, but your inverter’s battery current limit still applies.
Will my existing solar panels recharge the extra battery?
Check the math: array kWp × 4.2 peak sun hours × 0.80 gives your typical daily production. Your 4.68 kWp array makes about 15.7 kWh a day, which should comfortably refill about 10 kWh of added battery on a normal day while still running your daytime loads. On cloudy days it will charge less.
How much does it cost to add a battery in the Philippines?
As of November 23, 2026, a 10.24 kWh 51.2 V LiFePO4 pack costs about ₱58,000 to ₱82,000 and a 5.12 kWh pack about ₱33,000 to ₱42,000 at catalog street prices, before delivery and installation. DC cable, breaker and busbar add roughly ₱3,500 to ₱9,000.
Do I need a PEE to add a battery?
Yes for the final design. The cable, breaker and busbar sizes this page shows are typical estimates for review. A licensed Professional Electrical Engineer must size and sign off the work, as required for solar installations under the Philippine Electrical Code and DOE rules.
Planning a full system?
Open the builder for panels, inverter and a bill-of-materials guide, or check a contractor quote.
Open the Solar Builder → Is my quote fair? Find PH stockists
Estimates only. Cable, breaker and battery-bank sizing must be done and signed off by a licensed Professional Electrical Engineer (PEE) under the Philippine Electrical Code and DOE rules.