Learning Center · Batteries
How Many Hours Will a 5kWh, 10kWh or 16kWh Battery Run an Inverter Aircon?
A 1.0 HP inverter aircon on Eco with a fridge, Wi-Fi and two fans runs about 5.0 hours on 5 kWh, 10.0 hours on 10 kWh and 16.0 hours on 16 kWh. A 1.5 HP runs about 4.0, 8.1 and 12.9 hours. Formula: battery kWh × 0.9 × 0.94 ÷ average kW.
How many hours will a 5 kWh, 10 kWh or 16 kWh battery run an aircon?
For a 1.0 HP inverter aircon on Eco with a fridge, Wi-Fi and two fans, a 5 kWh battery lasts about 5.0 hours, a 10 kWh battery about 10.0 hours and a 16 kWh battery about 16.0 hours. For a 1.5 HP aircon the same batteries last about 4.0, 8.1 and 12.9 hours. For a full 8-hour night, a 10 kWh battery just covers either aircon, and 16 kWh gives margin for hot nights.
How much energy do you really get from a 5, 10 or 16 kWh battery?
A battery label shows total capacity. Two things take a share before the energy reaches your aircon: we plan to use only 80% of the label (we leave 20% unused to protect battery life, since deep, repeated discharges wear a battery out sooner), and the inverter wastes about 6% as heat. We use the same rule as the Builder and the battery calculator.
| Battery label | Usable energy (× 0.8 × 0.94) | Rounded |
|---|---|---|
| 5 kWh | 5 × 0.752 = 3.76 kWh | about 3.8 kWh |
| 10 kWh | 10 × 0.752 = 7.52 kWh | about 7.5 kWh |
| 16 kWh | 16 × 0.752 = 12.03 kWh | about 12.0 kWh |
How long will each battery run an aircon?
| Load | Average draw | 5 kWh battery | 10 kWh battery | 16 kWh battery |
|---|---|---|---|---|
| 1.0 HP, aircon only | 540 W | 7.0 h | 13.9 h | 22.3 h |
| 1.0 HP, aircon + fridge, Wi-Fi, 2 fans | 753 W | 5.0 h | 10.0 h | 16.0 h |
| 1.5 HP, aircon only | 720 W | 5.2 h | 10.4 h | 16.7 h |
| 1.5 HP, aircon + fridge, Wi-Fi, 2 fans | 933 W | 4.0 h | 8.1 h | 12.9 h |
Assumptions: inverter aircon at 60% duty (average 540 W for 1.0 HP, 720 W for 1.5 HP); inverter fridge average 48 W; Wi-Fi router 15 W; two ceiling fans at 75 W each. The other loads add 213 W. Planning estimates, not brand data.
What if the aircon works harder than Eco?
The 60% figure is our planning average. A small, shaded, well-insulated room may need less. A west-facing room in April, with the door opening often, may need much more. Here is the effect, with the other loads included.
| Aircon and how hard it works | Average draw (with fridge, Wi-Fi, fans) | 5 kWh | 10 kWh | 16 kWh |
|---|---|---|---|---|
| 1.0 HP at 40% duty | 573 W | 6.6 h | 13.1 h | 21.0 h |
| 1.0 HP at 60% duty | 753 W | 5.0 h | 10.0 h | 16.0 h |
| 1.0 HP at 80% duty | 933 W | 4.0 h | 8.1 h | 12.9 h |
| 1.0 HP at 100% duty | 1113 W | 3.4 h | 6.8 h | 10.8 h |
| 1.5 HP at 40% duty | 693 W | 5.4 h | 10.9 h | 17.4 h |
| 1.5 HP at 60% duty | 933 W | 4.0 h | 8.1 h | 12.9 h |
| 1.5 HP at 80% duty | 1173 W | 3.2 h | 6.4 h | 10.3 h |
| 1.5 HP at 100% duty | 1413 W | 2.7 h | 5.3 h | 8.5 h |
The rule of thumb: if the room is hot, plan on the 80% rows. That cuts the runtime by roughly a quarter against the table above.
How did we get these numbers?
- Average aircon power = full running watts × duty. For 1.0 HP: 900 × 0.6 = 540 W.
- Add the other loads: fridge 120 W × 0.4 = 48 W, router 15 W, two fans 150 W. Total 213 W.
- Usable energy = battery kWh × 0.8 × 0.94. A 10 kWh battery gives 7.52 kWh.
- Hours = usable Wh ÷ average W. Example: 7,520 ÷ (540 + 213) = 10.0 hours.
Does the inverter matter too?
Yes. The battery sets how long, the inverter sets how much at once. Add the running watts of everything that can be on together, then multiply by 1.25.
| Aircon | Running watts (full power) | Smallest inverter to consider | Why |
|---|---|---|---|
| 1.0 HP inverter | about 900 W + 213 W other loads | 2 kW (3 kW comfortable) | (900 + 213) × 1.25 = about 1.4 kW, so 2 kW is the minimum and 3 kW is comfortable |
| 1.5 HP inverter | about 1,200 W + 213 W other loads | 3 kW | (1,200 + 213) × 1.25 = about 1.8 kW, so 2 kW is the bare minimum; 3 kW leaves room for a TV or kettle |
| 2 aircons at once | about 2,100 W + 213 W | 5 kW | Add the running watts of both, then × 1.25 |
Also check the battery’s own limit. Most 5 kWh to 16 kWh home batteries can supply well over 1 kW, but read the maximum continuous discharge on the datasheet. For a deeper look at battery types, read our battery guide.
Which battery size should I pick for an aircon?
| Your goal | Pick | Notes |
|---|---|---|
| A few hours of aircon during brownouts | 5 kWh | About 5 hours of a 1.0 HP with other loads, or 4 hours of a 1.5 HP |
| Sleep all night with one 1.0 HP aircon | 10 kWh | About 10.0 hours with the other loads |
| Sleep all night with one 1.5 HP aircon | 10 kWh (tight) or 16 kWh | About 8.1 hours on 10 kWh, 12.9 hours on 16 kWh, with the other loads |
| Two aircons overnight | 16 kWh or more | Two 1.0 HP units on Eco run about 9 hours on 16 kWh with the other loads. Consider two batteries for hot nights. |
| Daytime aircon on solar plus a small backup | 5 to 10 kWh | Panels carry the aircon during the day, the battery covers evening and outages |
Try it with your own appliances: the Builder has an appliance picker with these exact aircon and fridge figures, and the battery calculator turns your loads and hours into a battery size. For the solar side, read how to size solar from your Meralco bill and hybrid vs grid-tie vs off-grid. Wiring? See how home solar is wired.
Frequently asked questions
How long will a 5 kWh battery run an aircon?
A 5 kWh battery holds about 3.8 kWh of usable energy. An inverter aircon of 1.0 HP, running on Eco, averages about 540 W by our planning figure, so the battery runs it for about 7.0 hours alone, or about 5.0 hours with a fridge, Wi-Fi and two fans. A 1.5 HP unit gets about 5.2 hours alone and 4.0 hours with the other loads.
How long will a 10 kWh battery run a 1.5 HP aircon?
About 10.4 hours for the aircon alone and about 8.1 hours with a fridge, Wi-Fi router and two fans, using 7.52 kWh usable and an average aircon draw of 720 W. A full night of 8 hours just fits, with almost no spare, so choose 16 kWh if you want margin.
What does the 0.8 × 0.94 mean?
The 0.8 is the share of the battery we plan to use (80% depth of discharge). We deliberately leave 20% unused to protect battery life, because deep, repeated discharges wear a battery out faster. Some lithium batteries allow 90% or more, so you may get a little extra in an emergency. The 0.94 is the inverter’s efficiency when it turns battery DC into household AC. A battery labelled 10 kWh gives about 7.52 kWh at your outlets.
Is 'Eco' mode really lower power?
Eco or auto mode lets the compressor slow down or switch off once the room is at the set temperature, so the average draw is lower than the nameplate. We assume a 60% duty, meaning the average is 60% of full power. In a hot, humid room, or with the door opening a lot, the duty is higher and the runtime is shorter. Use the 80% and 100% rows in the sensitivity table to see the effect.
Do I need a bigger inverter than the aircon's wattage?
Yes. Inverter aircons start gently, but the inverter must still cover the aircon’s full running power plus every other load at the same moment, then add about 25% margin. Check the inverter’s continuous rating, not only its surge rating.
Can solar panels charge the battery and run the aircon in the daytime?
Yes, if you have enough panels. A 1.5 HP inverter aircon at 8 hours a day uses about 5.8 kWh a day (1,200 W × 0.6 × 8 h). Our sizing needs about 1.6 kWp of panels for that alone (5.76 ÷ (4.5 × 0.8)), or about 2.0 kWp with the 1.25 rainy-season factor. Use the Builder to size your own.
Will an aircon run all night off a battery?
Possibly. Eight hours of a 1.0 HP aircon needs about 4.3 kWh and a 1.5 HP unit needs about 5.8 kWh from the aircon alone. Divide by 0.752 to find the battery label: about 5.7 kWh and 7.7 kWh. With the other loads, add 2.3 kWh to either figure.
Is a 16 kWh battery enough for two aircons?
For about a night, yes for two 1.0 HP units on Eco: they average about 1,080 W, plus 213 W of other loads, so about 9.3 hours. With two 1.5 HP units the average is about 1,440 W and the runtime drops to about 7.3 hours. Also check the battery’s maximum continuous discharge current and the inverter size.
Size the battery for your own aircon
Pick your aircon and appliances in the Builder, or run the battery calculator.
Open the BuilderBattery calculatorSources and last checked
Checked November 22, 2026. SunTipid is not a law firm or an engineering firm. This is general information, not legal or engineering advice. Runtimes are planning estimates. Real use depends on room, weather, temperature setting and the aircon model.
- SunTipid Builder appliance table (typical Philippine ratings: inverter aircon 1.0 HP 900 W and 1.5 HP 1,200 W at 60% duty, inverter fridge 120 W at 40%, router 15 W, ceiling fan 75 W).
- SunTipid Methodology page and battery calculator: battery usable energy = label kWh × 0.8 depth of discharge (80%, to protect battery life) × 0.94 inverter efficiency.
- Your aircon nameplate or manual for its rated running watts, and your battery datasheet for usable capacity and maximum discharge current.